Autoclave RSWKO6600 Repair Kit
Principle of Operation:
Parker Autoclave Engineers check valves provide uni-directional flow and shut-off for liquids and gases with high reliability.
O-Ring Type Excess Flow Valve Features (type SWKO):
Protects pressure gauges and other pressure instrumentation from sudden surges in flow due to operator error or line failure. This valve provides dependable, tight shut-off.
Vertical Installation: Since this type of check valve employs a non-spring loaded poppet, valve MUST be installed in VERTICAL position with arrow on valve body pointing UP (cover gland up).
Resetting Valve: Equalize the pressure across the poppet. The poppet will drop and reset automatically.
Autoclave RSWKO6600 Repair Kit Technical Data:
- Description: Repair Kit for model SWKO6600 O-Ring Type Excess Flow Valve
- Connections: 3/8″ Low Pressure (SW375)
- Pressure Rating: 15,000 psig
- Typical Spare Parts Included: Cover (316SS); O-Ring (FKM); Sleeve (316SS) (these items are highlighted in BLUE in the images below)
Please contact our Sales Department for assistance in selecting the right products for your application.