Autoclave CB5501 O-ring Check Valve
Ultra High Pressure Cone & Thread, Pressures to 150,000 psi
Prevent reverse flow where leak-tight shutoff is not mandatory. When differential pressure drops below cracking pressure, the valve closes. With all-metal components, the valve can be used up to 600F.
Autoclave CB5501 O-ring Check Valve Technical Data:
- Description: 5/16″ Ultra High Pressure O-Ring Check Valve
- Size: 5/16″
- Connection Type: F312C150
- Pressure Rating: 150,000 psi
- Orifice Diameter: 0.094″
- Cv: 0.11
- Hex Size: 1.75″
- Length: 5.50″
- Temperature: With all-metal components, valve can be used up to 600F. Minimum standard operating temperature is 0F.
- Cracking Pressure: 20 psi, +/- 30%. No optional cracking pressures available.
- Installation: Vertical or horizontal as required. Flow direction arrow marked on valve body.
- Repair Kit: Check valves are easily repaired. Add “R” to front of valve part number for corresponding repair kit. See “Cover Torque” value for re-assembly.
Please contact our Sales Department for assistance in selecting the right products for your application.
Product Catalog: Parker Autoclave Ultra High Pressure Fittings & Tubing