Principle of Operation:
Parker Autoclave Engineers Tube Caps are used to seal the ends of tubing. Caps are used when pressure testing lengths of tubes or capping off sections of systems for isolation or pressure tests.
Connection Type:
- HIGH PRESSURE: The High Pressure connection is a refinement of the original cone & thread joint which has been the standard connection in high pressure technology since its development by an agency of the US Government over 90 years ago. The pressure hand
Autoclave 150TC5C Tube Cap Technical Data:
- Description: 5/16″ High Pressure Tube Cap
- Connection Size & Type: 5/16″ High Pressure (F312C150)
- Pressure Rating: 150,000 psi
- Dimension “A” (Hex Size): 1.19″
- Dimension “B” (Length): 2.63″
- Material of Construction: All Parker Autoclave Engineers adapters are precision machined from cold-worked type 316 stainless steel. Other materials available on special order.
Notes:
- The maximum pressure rating for an adapter is determined by the connection component with the LOWEST pressure rating.
- All dimensions are for reference only and are subject to change.
Please contact our Sales Department for assistance in selecting the right products for your application.