Autoclave CLFX9900 Dual Disc Line Filter
Medium Pressure “Slimline SF” Cone & Thread, Pressures to 20,000 psi
Dual disc line filters are utilized in numbers industrial, chemical processing, aerospace, nuclear and other applications. With the dual disc design, large contaminant particles are trapped by the upstream filter element before they can reach and clog the smaller micron-size downstream element. Filter elements can be easily replaced.
Autoclave CLFX9900 Dual Disc Line Filter Technical Data:
- Description: 9/16″ Medium Pressure Dual Disc Line Filter
- Size: 9/16″
- Connection Type: SF562CX
- Pressure Rating: 20,000 psi
- Orifice Diameter: 0.250″
- Micron Size: 35/65 (downstream/upstream)
- Element Area: 0.25 in2
- Hex Size: 1.38″
- Length: 4.94″
- Materials: Body, Cover and Gland Nut all CW 316 Stainless Steel
- Element Material: 316L Stainless Steel, sintered disc type.
- Temperature: -100F to +650F
- Spare Parts: filter elements are the only replaceable part.
- Element Part Number(s): P-0794 (35-micron); P-0764 (65-micron)
Notes:
- All filters furnished complete with connection components unless otherwise specified. All dimensions for reference only and subject to change. Limited special material options are available, consult FPCC for assistance.
- Parker Autoclave disc and cup type filters are designed to filter small amounts of process particles. It is recommended that all fluids are thoroughly cleaned prior to entering the higher pressure system.
- Special material filters may be supplied with four flats in place of standard hex.
- Pressure differential not to exceed 1000 psi in a flowing condition. Filter replacement is recommended if differential pressure exceeds 1000 psi.
- Larger micron size filter element is installed on the upstream (inlet) side.
Please contact our Sales Department for assistance in selecting the right products for your application.
Product Catalog: Parker Autoclave Medium Pressure Fittings & Tubing