Autoclave CXK1202 Ball Type Excess Flow Valve
Medium Pressure “Slimline SF” Cone & Thread, Pressures to 20,000 psi
Protects pressure gauges and pressure instrumentation from sudden surges in flow or venting in the event of line failure.
Autoclave CXK1202 Ball Type Excess Flow Valve Technical Data:
- Description: 3/4″ Medium Pressure Ball Type Excess Flow Valve
- Size: 3/4″
- Connection Type: SF750CX
- Pressure Rating: 20,000 psi
- Orifice Diameter: 0.516″
- Cv: 0.368 (check flow – water, GPM)
- Hex Size: 1.75″
- Length: 5.12″
- Temperature: With all-metal components, Excess Flow Valves can be used from -423F to +800F.
- Resetting Valve: Equalize the pressure across the ball. The ball will drop and reset automatically. NOTE: when in checked position, a small flow is permitted through the valve.
- Installation: Since this type of valve employs a non-spring loaded ball, the valve MUST be installed in a VERTICAL position with the arrow on the valve body pointing UP.
- Repair Kit: Excess Flow Valves are easily repaired. Add “R” to front of valve part number for corresponding repair kit. See “Cover Torque” value for re-assembly.
- Cover Torque: 230 ft-lb
Please contact our Sales Department for assistance in selecting the right products for your application.