Haskel 8AGD-1 Gas Booster
Features & Benefits:
- Reliable, easy to maintain, compact and robust
- No heat, flame or spark risk
- Infinitely variable cycling speed and output
- Pneumatic driven units do not require electrical connections
- Easy to apply automatic controls
- No limit or adverse affect to continuous stop/start applications
- Seal systems designed for long working life
- No air line lubricator required
- Hydrocarbon free – separation between air and gas sections
- Built-in cooling (most models)
- Suitable for most gases
- Ability to stall at any predetermined pressure and hold the fixed pressure without consuming power or generating heat
Technical Data:
- Drive Size: 8″
- Ratio: 1:1
- Min GAS supply pressure: ATM
- Max GAS supply pressure: 300 psi
- Max rated GAS outlet pressure: 300 psi
- Static outlet stall pressure formula: 1.5 Pa + Ps (Pa = air drive pressure; Ps = gas supply pressure)
- Min AIR drive pressure: 20 psi
- Max AIR drive pressure: 130 psi
Sample Performance Characteristics:
- Boost 60 SCFM Gas from 70 psi to 140 psi while using 75 SCFM Air @ 90 psig supply pressure
- Boost 76 SCFM Gas from 90 psi to 160 psi while using 75 SCFM Air @ 90 psig supply pressure
- Boost 91 SCFM Gas from 110 psi to 180 psi while using 75 SCFM Air @ 90 psig supply pressure
- Boost 128 SCFM Gas from 130 psi to 180 psi while using 75 SCFM Air @ 90 psig supply pressure
Physical Characteristics:
- Unit weight: 121 lbs.
- Displacement / cycle: 400 cu. in.
- Max cycles: 50/min.
- GAS inlet/outlet connections: 3/4″ FNPT
- AIR drive inlet port: 3/4″ FNPT
Haskel 8AGD-1 Gas Booster Repair kit information:
- Gas section seal kit P/N: 55771
- Air drive section seal kit P/N: 50168
- Air valve seal kit P/N: 50881
- Optional tools: 28584 (Sleeve Removal Tool)
- Notes: 55771 kit includes piston & check valve seals.
Optional Modifications:
- C-13: Air filter, regulator with gauge, and manual start/stop
- 17860: Electrical stroke counter
- 25721: Mechanical stroke counter
- 29125: External pilot modification
- 50606: Low permeability seals for CO2 gas service
- 54312: Extreme service cycling modification
- 54827: Level II cleaning and certification of gas sections
- 56611-2: Vent purge with 15 psi relief
- 57875: Panel with regulator for mounting remote APS
- 59888: Cycle timer
- 80862: Viton air drive seals
- 82500: ATEX modification
- 86337: Extended life air drive seals
To add any modifications to this booster or for assistance in selecting the right booster for your application, please contact our Sales Department for assistance.
Product Catalog: Gas Booster Catalog