Haskel logo
Haskel Gas Booster System

Systems

Gas Booster System Features:

  • Pressurize gas from industrial gas bottles (up to 20,000 psig)
  • Plumbed for inert gases in singe arrangements
  • Available in single-stage or two-stage styles; selection is made on the grounds of gas pressure and flow requirements
  • Supplied with a range of controls: air controls, air pilot switches (optional) for automated start/stop control, relief device, pressure isolation and vent valves
  • All components are mounted and plumbed in an open stainless steel frame with a sloped front control panel
  • Safety relief devices are standard on all gas booster systems for maximum operational safety
  • Allows 90 to 95% use of cylinder gas to maintain process pressure when cylinder pressure drops
  • Oxygen cleaned units available
  • Can charge a received to ever higher-pressure level, thus storing a volume of gas for rapid release

Gas Booster System Applications:

  • Gas accumulator charging
  • Pressure & leak testing various pressure containing components
  • Pressurization of gas cylinders
  • Gas transfer, boosting or mixing

Scope of Supply

  1. Air-driven gas booster with external pilot modification to enable use of air pilot switches to automatically start/stop the booster.
  2. Adjustable inlet air pilot switch used to stop booster when the gas supply pressure falls below the adjusted minimum set point (optional).
  3. Adjustable remote-set outlet air pilot switch used to stop booster when the outlet pressure reaches the adjusted maximum set point (optional).
  4. Outlet pressure gauge, safe case design, 100mm diameter, panel mounted with bar/psi dual scale. Accuracy +/- 1% FSD.
  5. Inlet pressure gauge, safe case design, 100mm diameter, panel mounted with bar/psi dual scale. Accuracy +/- 1% FSD.
  6. Gas filter, 5-micron rated, used to stop any ingested contamination from entering the booster (e.g. while changing out gas supply bottles).
  7. Roll bar frame with sloping operator panel into which the booster and controls are mounted. Frames are brushed 316 stainless steel.
  8. Combined air inlet filter regulator, with integral pressure gauge and on/off control valve. Air filter – inline with 40-micron filtration to maintain air drive quality. Adjustable air regulator used to set the air drive pressure, adjustable between 0 – 150 psi. 25mm air gauge to indicate the regulated air pressure setting. Manual on/off valve and speed control valve, panel mounted, used to adjust the cycling speed at which the booster operates.
  9. Adjustable Haskel relief valve used to protect the booster and other components from over pressurization, piped to a common vent connection.
  10. Adjustable remote-set air pilot regulator used to change the set point for the remote-set outlet air pilot switch (optional).
  11. 25mm air gauge, panel mounted, used to indicate the adjustable remote-set regulator adjusted pressure.
  12. Manually operated Butech outlet isolation valve, panel mounted, piped to a common vent connection.
  13. Manually operated Butech outlet pressure vent valve, panel mounted, piped to a common vent connection.
  14. Interstage cooler. A Haskel design integral tube and shell cooler used to reduce the boosted gas temperature.
Haskel Gas Booster System schematic

Standard Gas Booster Systems Model Section Chart

System Model Number

Booster Model Number

Max Gas Supply Press

Min Gas Supply Press

Max Gas Outlet Press

Static Outlet Stall Pressure

4AG-25
AGD-1.5
AGD-4
AGD-7
AGD-14
AGD-15
AGD-30
AGD-32
AGD-62
AGD-75
AGD-152
AGT-4
AGT-7/15
AGT-7/30
AGT-14/62
AGT-15/30
AGT-15/75
AGT-30/75
AGT-32/62
AGT-32/152
AGT-62/152
AGT-62/152H
8AGD-2
8AGD-2.8
8AGD-5
8AGD-14
8AGD-30
8AGD-60
8AGT-5/14
8AGT-5/30
8AGT-14/30
8AGT-14/60
8AGT-30/60
4500 psi
300 psi
1250 psi
2500 psi
5000 psi
5000 psi
9000 psi
5000 psi
5000 psi
12000 psi
25000 psi
1250 psi
6 Pa to 2500*
2 Pa to 2500*
4Pa to 2500*
15 Pa to 2500*; 5000**
3.5 Pa to 5000*
20 Pa to 9000*
30 Pa to 2500*; 5000**
7 Pa to 5000*
40 Pa to 3600*; 9000**
40 Pa to 3600*; 9000**
300 psi
800 psi
2500 psi
5000 psi
5000 psi
9000 psi
2.8 Pa to 2500*
1 Pa to 2500*
12 Pa to 1190*; 2500**
4.3 Pa to 2500*
30 Pa to 2500*; 5000**
 
25 psi
ATM
ATM
25 psi
25 psi
50 psi
100 psi
50 psi
200 psi
250 psi
250 psi
1/4-ATM
25 psi
25 psi
25 psi
50 psi
100 psi
100 psi
100 psi
100 psi
100 psi
100 psi
ATM
ATM
50 psi
50 psi
50 psi
50 psi
25 psi
25 psi
25 psi
25 psi
25 psi
 
4500 psi
300 psi
1250 psi
2500 psi
5000 psi
5000 psi
9000 psi
5000 psi
9000 psi
12000 psi
25000 psi
1250 psi
5000 psi
9000 psi
9000 psi
9000 psi; 5000**
15000 psi
15000 psi
9000 psi; 5000**
15000 psi
20000 psi; 9000**
25000 psi; 9000**
300 psi
800 psi
2500 psi
5000 psi
5000 psi
9000 psi
2500 psi
5000 psi
5000 psi; 2500**
9000 psi
9000 psi; 5000**
25 Pa
1.5 Pa + Ps
4 Pa + Ps
7 Pa + Ps
14 Pa + Ps
15 Pa + Ps
30 Pa + Ps
30 Pa + Ps
60 Pa + Ps
75 Pa + Ps
150 Pa + Ps
4 Pa + Ps
15 Pa + 2 Ps
30 Pa + 4 Ps
60 Pa + 4 Ps
30 Pa + 2 Ps
75 Pa + 5 Ps
75 Pa + 2.5 Ps
60 Pa + 2 Ps
150 Pa + 5 Ps
150 Pa + 2.5 Ps
150 Pa + 2.5 Ps
2 Pa + Ps
2.8 Pa + Ps
5 Pa + Ps
14 Pa + Ps
30 Pa + Ps
60 Pa + Ps
14 Pa + 2.8 Ps
30 Pa + 6 Ps
30 Pa + 2.1 Ps
60 Pa + 4.3 Ps
60 Pa + 2 Ps

Pa = Air Drive pressure; Ps = Gas Supply pressure

* Two-Stage models: supply pressure also limited by factor X air drive pressure (Pa) to avoid inter-stage stall.

** If outlet pressure exceeds maximum 1st stage pressure and supply pressure simultaneously exceeds pressure limit above the line, install inter-stage relief valve set at this pressure.

Oxygen Gas Booster Systems Model Section Chart

System Model Number

Booster Model Number

Max Gas Supply Press

Min Gas Supply Press

Max Gas Outlet Press

Static Outlet Stall Pressure

86921 (4AG-25)
52618 (AGD-1.5)
26266 (AGD-4)
51147 (AGD-7)
83008 (AGD-14)
27962 (AGD-15)
17495 (AGD-30)
52570 (AGD-32)
27961 (AGD-62)
51269 (AGD-75)
28597 (AGT-4)
51308 (AGT-7/15)
52065 (AGT-7/30)
28007 (AGT-15/30)
AGT-15/75
AGT-30/75
AGT-32/62
58675 (8AGD-2)
80642 (8AGD-2.8)
52623 (8AGD-5)
52612 (8AGD-14)
8AGD-30
52624 (8AGT-5/14)
52630 (8AGT-5/30)
8AGT-14/30
8AGT-14/60
8AGT-30/60
4500 psi
300 psi
1250 psi
2500 psi
5000 psi
5000 psi
9000 psi
5000 psi
5000 psi
12000 psi
1250 psi
6 Pa to 2500*
2 Pa to 2500*
15 Pa to 2500*; 5000**
3.5 Pa to 5000*
20 Pa to 9000*
30 Pa to 2500*; 5000**
300 psi
800 psi
2500 psi
5000 psi
5000 psi
2.8 Pa to 2500*
1 Pa to 2500*
12 Pa to 1190*; 2500**
4.3 Pa to 2500*
30 Pa to 2500*; 5000**
 
25 psi
ATM
ATM
25 psi
25 psi
50 psi
100 psi
50 psi
200 psi
250 psi
1/4-ATM
25 psi
25 psi
50 psi
100 psi
100 psi
100 psi
ATM
ATM
50 psi
50 psi
50 psi
25 psi
25 psi
25 psi
25 psi
25 psi
 
4500 psi
300 psi
1250 psi
2500 psi
5000 psi
5000 psi
5000 psi
5000 psi
5000 psi
5000 psi
1250 psi
5000 psi
5000 psi
5000 psi
5000 psi
5000 psi
5000 psi
300 psi
800 psi
2500 psi
5000 psi
5000 psi
2500 psi
5000 psi
5000 psi
5000 psi
5000 psi
25 Pa
1.5 Pa + Ps
4 Pa + Ps
7 Pa + Ps
14 Pa + Ps
15 Pa + Ps
30 Pa + Ps
30 Pa + Ps
60 Pa + Ps
75 Pa + Ps
4 Pa + Ps
15 Pa + 2 Ps
30 Pa + 4 Ps
30 Pa + 2 Ps
75 Pa + 5 Ps
75 Pa + 2.5 Ps
60 Pa + 2 Ps
2 Pa + Ps
2.8 Pa + Ps
5 Pa + Ps
14 Pa + Ps
30 Pa + Ps
14 Pa + 2.8 Ps
30 Pa + 6 Ps
30 Pa + 2.1 Ps
60 Pa + 4.3 Ps
60 Pa + 2 Ps

Pa = Air Drive pressure; Ps = Gas Supply pressure

* Two-Stage models: supply pressure also limited by factor X air drive pressure (Pa) to avoid inter-stage stall.

** If outlet pressure exceeds maximum 1st stage pressure and supply pressure simultaneously exceeds pressure limit above the line, install inter-stage relief valve set at this pressure.

For assistance with or additional information on any of these products, please contact sa***@fl*****************.com .